Thermostat - removal, testing and refitting

OHV engines Note: A new gasket must be used on refitting.

Removal
1 Drain the cooling system as described in Chapter 1.

2 Slacken the clips and disconnect the hoses at the thermostat housing (see illustration).

4.2 Expansion tank hose (A) and radiator top hose (B) connections at
4.2 Expansion tank hose (A) and radiator top hose (B) connections at thermostat housing - OHV engine

Disconnect the radiator fan thermal switch wiring plug.

3 Unscrew the two bolts and remove the thermostat housing cover. If it is tight carefully tap it with a soft-faced mallet.

4 Extract the thermostat (see illustration). If it is stuck tight in its seat, do not lever it out by its bridge piece, but cut round it with a very sharp knife.

4.4 Thermostat location in cylinder head - OHV engine
4.4 Thermostat location in cylinder head - OHV engine

Testing
5 To test the thermostat, first check that in a cold condition its valve plate is closed.

Suspend it on a string in a pan of cold water together with a thermometer (see illustration).

4.5 Testing the thermostat
4.5 Testing the thermostat

Heat the water and check that the thermostat starts to open at the temperature given in the Specifications. It is difficult to check that the thermostat opens fully, as this occurs at a temperature above the boiling point of water.

6 Remove the thermostat from the water and check that the valve closes as the unit cools.

If the thermostat does not operate as described, obtain a new thermostat.

Refitting
7 Refitting is the reverse sequence to removal, but ensure that all traces of old gasket are removed from the housing mating faces and use a new gasket lightly smeared with jointing compound. Tighten the retaining bolts to the specified torque.

8 On completion, refill the cooling system as described in Chapter 1.

CVH engines
Note: A new gasket must be used on refitting.

Removal
9 Drain the cooling system as described in Chapter 1.

10 Slacken the clips and disconnect the expansion tank hose, radiator hose and heater hose at the thermostat housing (see illustration).

4.10 Disconnect the expansion tank hose at the thermostat housing - CVH
4.10 Disconnect the expansion tank hose at the thermostat housing - CVH engine

11 Disconnect the radiator fan thermal switch wiring plug.

12 Unscrew the three bolts and remove the thermostat housing from the cylinder head. If it is stuck, tap it off carefully with a soft-faced mallet.

13 Extract the retaining spring clip and withdraw the thermostat from the housing followed by the sealing ring (see illustrations).

4.13a Extract the retaining spring clip (arrowed) . . .
4.13a Extract the retaining spring clip (arrowed) . . .

4.13b . . . withdraw the thermostat . . .
4.13b . . . withdraw the thermostat . . .

4.13c . . . and remove the sealing ring
4.13c . . . and remove the sealing ring

Testing and refitting 14 Proceed as described previously in this Section for OHV engines.

    See also:

    Switches - removal and refitting
    General 1 Disconnect the battery negative terminal before removing any switches. Pre-1986 models Wiper delay switch 2 Remove the switch knob and the bezel nut. 3 Withdraw the switch through the ...

    Facia - removal and refitting
    Pre-1986 models Removal 1 Disconnect the battery negative lead. 2 Remove the under-dash cover panels. 3 Refer to Chapter 10 and remove the steering column assembly. 4 Refer to Chapter 12 and rem ...

    General description
    The cooling system is of the pressurised pump-assisted thermo-syphon type. The system consists of the radiator, water pump, thermostat, electric cooling fan, expansion tank and associated hoses. ...