Waste gate solenoid control valve - removal and refitting
Removal
1 The solenoid control valve is mounted on a
bracket located underneath the ignition
distributor (see illustration).
21.1 Waste gate solenoid control valve location (arrowed)
2 Disconnect the battery negative lead.
3 Disconnect the solenoid wiring multi-plug.
4 Identify and mark the hose locations at the solenoid connections, then remove the hoses.
5 Undo the retaining screws and remove the unit from its location.
Refitting
6 Refitting is a reversal of removal.
See also:
Specifications
General
System type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . Bosch mechanical continuous injection system
Application:
XR3i and XR3i Cabriolet m ...
Seat belts - removal and refitting
Front belt - 3-door models
Note: Note the fitted sequence of any plates,
washers and spacers when unbolting the seat
belt anchors.
Removal
1 Slide the belt stalk cover upwards to
expose the anch ...
Battery terminal check (Every 12 000 miles (20 000 km) or 12 months)
Caution: Before carrying out
any work on the vehicle battery,
read through the precautions
given in “Safety first!” at the
beginning of this manual.
1 The battery fitted as original equipment is
...