Oil filler cap cleaning - OHVand HCS engines (Every 6000 miles or 6 months)
1 Simply pull the oil filler cap from the rocker cover and, where applicable, disconnect the hose(s) from the cap.
2 Inspect the filler cap, and if necessary clean the cap using clean petrol to remove any deposits.
3 Ensure that the cap is completely dry before refitting.
See also:
Load apportioning valve P100 models) - removal and refitting
Caution: Refer to the
precautions in Section 1.
Removal
1 Chock the front wheels, jack up the rear of
the vehicle and support on axle stands (see
“Jacking and Vehicle Support”).
2 The load appor ...
Valve block (ABS) - removal and refitting
Caution: Refer to the
precautions in Section 1.
Removal
1 Disconnect the battery negative lead.
2 Depressurise the hydraulic system by
pumping the brake pedal at least 20 times, or
until it beco ...
Distributor (OHC models) - removal and refitting
Note: During production the engine ignition
timing is accurately set using a microwave
process, and sealant is applied to the
distributor clamp bolt. Removal of the
distributor should be avoided e ...