Oil filler cap cleaning - OHVand HCS engines (Every 6000 miles or 6 months)
1 Simply pull the oil filler cap from the rocker cover and, where applicable, disconnect the hose(s) from the cap.
2 Inspect the filler cap, and if necessary clean the cap using clean petrol to remove any deposits.
3 Ensure that the cap is completely dry before refitting.
See also:
Throttle position sensor - removal and refitting
Note: During this procedure ensure that the
sensor wiper is not rotated beyond its normal
operating arc.
2.0 litre SOHC models
1 Disconnect the battery negative lead.
2 Free the throttle position ...
Fuel pressure regulator (models up to 1985) - removal and refitting
Caution: Refer to the
precautions in Section 1 before
proceeding.
Removal
1 The fuel pressure regulator is located on the
left-hand side of the engine compartment
(see illustration).
5.1 Fuel ...
Pistons and connecting rods - examination and renovation
1.8 litre (R2A type)
1 Examine the pistons for ovality, scoring,
and scratches. Check the connecting rods for
wear or damage.
2 The gudgeon pins are an interference fit in
the connecting rods, an ...