Oil filler cap cleaning - OHVand HCS engines (Every 6000 miles or 6 months)
1 Simply pull the oil filler cap from the rocker cover and, where applicable, disconnect the hose(s) from the cap.
2 Inspect the filler cap, and if necessary clean the cap using clean petrol to remove any deposits.
3 Ensure that the cap is completely dry before refitting.
See also:
Rear anti-roll bar (Saloon, Hatchback and Estate models) - removal and
refitting
Removal
1 Loosen the rear roadwheel nuts, chock the
front wheels, jack up the rear of the vehicle
and support on axle stands placed under the
side members.
2 Prise off the straps which connect th ...
Distributorless Ignition System (DIS) components - removal and
refitting
Electronic modules
1 Refer to Section 6.
DIS coil
2 Refer to Section 4.
Engine speed sensor
Removal
3 Disconnect the battery negative lead.
4 Disconnect the sensor wiring plug (see
illustratio ...
Ignition system component check (Every 24 000 miles (40 000 km) or 2 years)
1 Before disturbing any part of the ignition
system, disconnect the battery negative lead.
2 Identify and clearly mark all HT leads before
disconnecting them from the spark plugs.
3 Refer to the a ...