Oil filler cap cleaning - OHVand HCS engines (Every 6000 miles or 6 months)

1 Simply pull the oil filler cap from the rocker cover and, where applicable, disconnect the hose(s) from the cap.

2 Inspect the filler cap, and if necessary clean the cap using clean petrol to remove any deposits.

3 Ensure that the cap is completely dry before refitting.

    See also:

    Engine - refitting (automatic transmission in vehicle)
    1 Reverse the procedure described in Section 9, noting the following points. 2 Check that the engine adapter plate is correctly positioned on its locating dowels. 3 As the torque converter is only ...

    Master cylinder (conventional braking system) - removal, overhaul and refitting
    Note: Before commencing overhaul obtain a repair kit containing new pistons and seals. Caution: Refer to the precautions in Section 1. Removal 1 Depress the brake pedal several times to dissipat ...

    Exhaust emission control system components - removal and refitting
    Carburettor engines Spark delay/sustain valve Removal 1 Disconnect the vacuum lines at the valve and remove the valve from the engine. Refitting 2 When refitting a spark delay valve it must be ...