Oil filler cap cleaning - OHVand HCS engines (Every 6000 miles or 6 months)

1 Simply pull the oil filler cap from the rocker cover and, where applicable, disconnect the hose(s) from the cap.

2 Inspect the filler cap, and if necessary clean the cap using clean petrol to remove any deposits.

3 Ensure that the cap is completely dry before refitting.

    See also:

    Exhaust emission control system components - removal and refitting
    Carburettor engines Spark delay/sustain valve Removal 1 Disconnect the vacuum lines at the valve and remove the valve from the engine. Refitting 2 When refitting a spark delay valve it must be ...

    Rear wheel cylinder (drum brakes) - removal, overhaul and refitting
    Caution: Refer to the precautions in Section 1. Saloon, Hatchback and Estate models 1 Chock the front wheels, loosen the relevant roadwheel nuts, then jack up the rear of the vehicle and support ...

    General information and precautions
    The fuel system on all models with carburettor induction is composed of a centrally mounted fuel tank, a fuel pump, a carburettor and an air cleaner. The fuel tank is mounted under the floor pan ...