Oil filler cap cleaning - OHVand HCS engines (Every 6000 miles or 6 months)
1 Simply pull the oil filler cap from the rocker cover and, where applicable, disconnect the hose(s) from the cap.
2 Inspect the filler cap, and if necessary clean the cap using clean petrol to remove any deposits.
3 Ensure that the cap is completely dry before refitting.
See also:
Vacuum servo unit and linkage - removal and refitting
Removal
1 Refer to Section 12 and remove the master
cylinder.
2 On fuel-injection models unclip and lift out
the front section of the heater plenum
chamber to provide access to the connecting
li ...
Exhaust manifold - removal and refitting
Note: A new gasket will be required on
refitting.
Removal
1 Disconnect the battery negative lead.
2 On carburettor and CFI engine models
remove the air cleaner as described in the
appropriate Pa ...
Fuel cut-off (inertia) switch - removal and refitting
The procedure is as described in Part C of