Oil filler cap cleaning - OHVand HCS engines (Every 6000 miles or 6 months)

1 Simply pull the oil filler cap from the rocker cover and, where applicable, disconnect the hose(s) from the cap.

2 Inspect the filler cap, and if necessary clean the cap using clean petrol to remove any deposits.

3 Ensure that the cap is completely dry before refitting.

    See also:

    Crankshaft front oil seal - renewal
    Note: A suitable puller will be required to remove the crankshaft pulley. A new crankshaft pulley bolt, and a new lower timing chain cover gasket, must be used on refitting. 1 The crankshaft front ...

    Air cleaner assembly - removal and refitting
    Removal 1 Disconnect the battery negative terminal. 2 Disconnect the crankcase ventilation hoses which are accessible from above, from the air cleaner body (see illustration). 2.2 Disconnecting ...

    Coolant renewal (Every 24 000 miles or 2 Years)
    Cooling system draining 1 It is preferable to drain the system when the coolant is cold. If it must be drained when hot, release the pressure cap on the thermostat housing (or expansion tank on la ...