Oil filler cap cleaning - OHVand HCS engines (Every 6000 miles or 6 months)

1 Simply pull the oil filler cap from the rocker cover and, where applicable, disconnect the hose(s) from the cap.

2 Inspect the filler cap, and if necessary clean the cap using clean petrol to remove any deposits.

3 Ensure that the cap is completely dry before refitting.

    See also:

    Engine - removal leaving automatic transmission in vehicle
    Note: Refer to the warning at the beginning of Section 5 before proceeding. A suitable hoist and lifting tackle will be required for this operation. 1 Proceed as described in paragraphs 1 to 21 o ...

    Manifold Absolute Pressure (MAP) sensor - removal and refitting
    Removal 1 Disconnect the battery negative lead. 2 Disconnect the sensor wiring plug (see illustration). Do not pull on the wiring. 16.2 Manifold absolute pressure (MAP) sensor - 1.4 CFI engine ...

    Manifolds, exhaust and emission control systems
    All models utilise a light alloy inlet manifold which on carburettor models is coolant heated to improve the atomisation of the fuel/air mixture. The exhaust manifold is of cast iron construction ...