Oil filler cap cleaning - OHVand HCS engines (Every 6000 miles or 6 months)

1 Simply pull the oil filler cap from the rocker cover and, where applicable, disconnect the hose(s) from the cap.

2 Inspect the filler cap, and if necessary clean the cap using clean petrol to remove any deposits.

3 Ensure that the cap is completely dry before refitting.

    See also:

    Fuses and relays - location and renewal
    Location 1 The main fuses and relays are located in a box in the engine compartment on the righthand side of the bulkhead. The circuits protected are identified by symbols on the underside of the ...

    Exhaust manifold - removal and refitting
    Note: A new gasket will be required on refitting. Removal 1 Disconnect the battery negative lead. 2 On carburettor and CFI engine models remove the air cleaner as described in the appropriate Pa ...

    Steering column lock - removal and refitting
    Note: For ignition switch removal see Chapter 5. A new shear-bolt will be required on refitting. Removal 1 To remove the ignition switch/column lock, the shear-head bolt must be drilled out. 2 A ...