Oil filler cap cleaning - OHVand HCS engines (Every 6000 miles or 6 months)
1 Simply pull the oil filler cap from the rocker cover and, where applicable, disconnect the hose(s) from the cap.
2 Inspect the filler cap, and if necessary clean the cap using clean petrol to remove any deposits.
3 Ensure that the cap is completely dry before refitting.
See also:
Fuses and relays - location and renewal
Location
1 The main fuses and relays are located in a
box in the engine compartment on the righthand
side of the bulkhead. The circuits
protected are identified by symbols on the
underside of the ...
Exhaust manifold - removal and refitting
Note: A new gasket will be required on
refitting.
Removal
1 Disconnect the battery negative lead.
2 On carburettor and CFI engine models
remove the air cleaner as described in the
appropriate Pa ...
Steering column lock - removal and refitting
Note: For ignition switch removal see
Chapter 5. A new shear-bolt will be
required on refitting.
Removal
1 To remove the ignition switch/column lock,
the shear-head bolt must be drilled out.