Specifications
Battery
Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . 12 volt lead-acid, 35 to 52 Ah depending on model
Charge condition:
Poor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . 12.4 volts or less
Normal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . 12.6 volts
Good . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . 12.7 volts or over
Alternator
Minimum brush length:
Bosch, Lucas and Mitsubishi . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . 5.0 mm
Motorola . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . 4.0 mm
Regulator voltage at 4000 rpm with 3 to 7A load (all models) . . . . . . . .
13.7 to 14.6 volts
Starter motor
Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . Pre-engaged
Make:
Bosch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . 0.8 kW, 0.85 kW, 0.9 kW, 0.95 kW
Lucas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . 8M 90, 9M 90, M 79
Nippondenso . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . 0.6 kW, 0.9 kW
Minimum brush length:
Bosch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . 10.0 mm
Lucas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . 8.0 mm
Nippondenso 0.6 kW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . 10.0 mm
Nippondenso 0.9 kW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . 9.0 mm
See also:
Airflow meter - removal and refitting
Note: A tachometer and an exhaust gas
analyser will be required to check the idle
mixture on completion.
1 Disconnect the battery negative lead.
2 Depress the locking clip on the airflow
meter wi ...
Sump - removal and refitting
Warning: A new sump gasket will
be required on refitting, and
suitable sealing compound will
be required to coat the sump and
cylinder block mating faces.
Shims may be required when mating the
e ...
Air cleaner assembly - removal and refitting
Removal
1 Disconnect the battery negative terminal.
2 Disconnect the crankcase ventilation hoses
which are accessible from above, from the air
cleaner body (see illustration).
2.2 Disconnecting ...
