Speedometer cable - removal and refitting

Removal
1 Disconnect the battery and remove the instrument panel as described in Section 9.

2 Disconnect the cable from the transmission and release it from its clips and grommet.

3 Withdraw the cable through the bulkhead.

Refitting
4 Refitting is a reversal of removal. The inner and outer cables are supplied as a complete assembly.

    See also:

    Air cleaner inlet air temperature control check (Every 24 000 miles (40 000 km) or 2 years)
    SOHC and DOHC carburettor models 1 A vacuum pump will be required to test the control components. 2 To check the operation of the air temperature control, the engine must be cold. First observe ...

    Fuses and relays - location and renewal
    Location 1 The main fuses and relays are located in a box in the engine compartment on the righthand side of the bulkhead. The circuits protected are identified by symbols on the underside of the ...

    Oil pump - removal and refitting
    Note: A suitable puller will be required to remove the crankshaft pulley. A new crankshaft pulley bolt, a new lower timing chain cover gasket, and a new oil pump gasket, must be used on refitting. ...