Speedometer cable - removal and refitting
Removal
1 Disconnect the battery and remove the
instrument panel as described in Section 9.
2 Disconnect the cable from the transmission and release it from its clips and grommet.
3 Withdraw the cable through the bulkhead.
Refitting
4 Refitting is a reversal of removal. The inner
and outer cables are supplied as a complete
assembly.
See also:
Air cleaner inlet air temperature control check (Every 24 000 miles (40 000
km) or 2 years)
SOHC and DOHC carburettor
models
1 A vacuum pump will be required to test the
control components.
2 To check the operation of the air
temperature control, the engine must be cold.
First observe ...
Fuses and relays - location and renewal
Location
1 The main fuses and relays are located in a
box in the engine compartment on the righthand
side of the bulkhead. The circuits
protected are identified by symbols on the
underside of the ...
Oil pump - removal and refitting
Note: A suitable puller will be required to
remove the crankshaft pulley. A new
crankshaft pulley bolt, a new lower timing
chain cover gasket, and a new oil pump
gasket, must be used on refitting. ...