Accelerator pedal - removal and refitting

The procedure is the same as described in Part A of this Chapter for carburettor models.

    See also:

    Fuel pressure regulator - removal and refitting
    Removal 1 Remove the CFI unit as described in Section 8. 2 Remove the four screws securing the regulator housing to the CFI unit, then carefully lift off the housing and recover the ball, cup, la ...

    Contact breaker points adjustment - models with contact breaker distributor (Every 6000 miles or 6 months)
    1 Spring back the retaining clips or undo the screws as appropriate and lift off the distributor cap. 2 Withdraw the rotor arm from the distributor shaft. 3 Using a screwdriver, gently prise the ...

    Ford VV carburettor automatic choke components - removal, checking and refitting
    Bi-metal housing Note: A new gasket will be required on refitting. Removal 1 Disconnect the battery negative lead. 2 Remove the air cleaner as described in Section 2. 3 Release any pressure in ...