Accelerator pedal - removal and refitting
The procedure is the same as described in Part A of this Chapter for carburettor models.
See also:
Fuel pressure regulator - removal and refitting
Removal
1 Remove the CFI unit as described in Section 8.
2 Remove the four screws securing the
regulator housing to the CFI unit, then carefully
lift off the housing and recover the ball, cup,
la ...
Contact breaker points adjustment - models with contact breaker
distributor (Every 6000 miles or 6 months)
1 Spring back the retaining clips or undo the
screws as appropriate and lift off the
distributor cap.
2 Withdraw the rotor arm from the distributor
shaft.
3 Using a screwdriver, gently prise the
...
Ford VV carburettor automatic choke components - removal,
checking and refitting
Bi-metal housing
Note: A new gasket will be required on
refitting.
Removal
1 Disconnect the battery negative lead.
2 Remove the air cleaner as described in
Section 2.
3 Release any pressure in ...