Oil filler cap cleaning - OHVand HCS engines (Every 6000 miles or 6 months)

1 Simply pull the oil filler cap from the rocker cover and, where applicable, disconnect the hose(s) from the cap.

2 Inspect the filler cap, and if necessary clean the cap using clean petrol to remove any deposits.

3 Ensure that the cap is completely dry before refitting.

    See also:

    Fuel-injection control module - removal and refitting
    Removal 1 The fuel-injection control module is only used on KE-Jetronic systems and is located in the engine compartment behind the heater plenum chamber and fan motor. 2 Disconnect the battery n ...

    Throttle housing - removal and refitting
    Note: A new gasket must be used on refitting. Removal 1 Disconnect the battery negative lead. 2 Depressurise the fuel system as described in Section 6. 3 Remove the air inlet pipe (see illustrati ...

    Crankcase ventilation system check (Every 12 000 miles (20 000 km) or 12 months)
    1 Inspect the crankcase ventilation system for blockage or damage. A blocked hose can cause a build-up of crankcase pressure, which in turn can cause oil leaks (see illustration). 35.1 Loosenin ...