Oil filler cap cleaning - OHVand HCS engines (Every 6000 miles or 6 months)

1 Simply pull the oil filler cap from the rocker cover and, where applicable, disconnect the hose(s) from the cap.

2 Inspect the filler cap, and if necessary clean the cap using clean petrol to remove any deposits.

3 Ensure that the cap is completely dry before refitting.

    See also:

    Crankshaft and bearings - examination and renovation
    1 Examine the bearing surfaces of the crankshaft for scratches or scoring and, using a micrometer, check each journal and crankpin for ovality. Where this is found to be in excess of 0.0254 mm (0. ...

    Carburettor (Weber 2V type) - fast idle speed adjustment
    1 This procedure does not apply to models fitted with a carburettor stepper motor, for which no adjustment is possible. 2 Check the idle speed and mixture. The idle speed must be correct before at ...

    Idle Speed Control Valve (ISCV) - removal, cleaning and refitting
    Removal 1 Disconnect the battery negative lead. 2 Disconnect the valve wiring plug (see illustration). 12.2 Idle speed control valve - 1.6 EFI engine A Wiring plug B Securing bolts 3 Unscrew t ...