Oil filler cap cleaning - OHVand HCS engines (Every 6000 miles or 6 months)

1 Simply pull the oil filler cap from the rocker cover and, where applicable, disconnect the hose(s) from the cap.

2 Inspect the filler cap, and if necessary clean the cap using clean petrol to remove any deposits.

3 Ensure that the cap is completely dry before refitting.

    See also:

    Timing belt and sprockets - removal and refitting
    Note: Refer to the warning in Section 8 before proceeding. On models from mid-1985 (without a timing belt tensioner spring) the belt tension should be checked using Ford special tool No 21-113 aft ...

    Specifications
    Torque wrench setting Nm lbf ft All seat belt anchor bolts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 to 41 21 to 30 ...