Oil filler cap cleaning - OHVand HCS engines (Every 6000 miles or 6 months)
1 Simply pull the oil filler cap from the rocker cover and, where applicable, disconnect the hose(s) from the cap.
2 Inspect the filler cap, and if necessary clean the cap using clean petrol to remove any deposits.
3 Ensure that the cap is completely dry before refitting.
See also:
Crankshaft and bearings - examination and renovation
1 Examine the bearing surfaces of the
crankshaft for scratches or scoring and, using
a micrometer, check each journal and
crankpin for ovality. Where this is found to be
in excess of 0.0254 mm (0. ...
Carburettor (Weber 2V type) - fast idle speed adjustment
1 This procedure does not apply to models
fitted with a carburettor stepper motor, for
which no adjustment is possible.
2 Check the idle speed and mixture. The idle
speed must be correct before at ...
Idle Speed Control Valve (ISCV) - removal, cleaning and
refitting
Removal
1 Disconnect the battery negative lead.
2 Disconnect the valve wiring plug (see
illustration).
12.2 Idle speed control valve - 1.6 EFI engine
A Wiring plug B Securing bolts
3 Unscrew t ...