Oil filler cap cleaning - OHVand HCS engines (Every 6000 miles or 6 months)

1 Simply pull the oil filler cap from the rocker cover and, where applicable, disconnect the hose(s) from the cap.

2 Inspect the filler cap, and if necessary clean the cap using clean petrol to remove any deposits.

3 Ensure that the cap is completely dry before refitting.

    See also:

    Ignition timing (OHC models) - adjustment
    Note: During production the ignition timing is accurately set using a microwave process, and sealant is applied to the distributor clamp bolt. Because the electronic components require no maintena ...

    Ignition HT coil - testing, removal and refitting
    Note: Refer to the precautions given in Section 1 before proceeding. All except models with DIS ignition system Testing 1 Accurate checking of the coil output requires the use of special test eq ...

    Handbrake cables - renewal
    1 Chock the front wheels, then fully release the handbrake. 2 Raise and support the vehicle at the rear with axle stands (see “Jacking and Vehicle Support”). Primary cable 3 Extract the spring c ...