Oil filler cap cleaning - OHVand HCS engines (Every 6000 miles or 6 months)
1 Simply pull the oil filler cap from the rocker cover and, where applicable, disconnect the hose(s) from the cap.
2 Inspect the filler cap, and if necessary clean the cap using clean petrol to remove any deposits.
3 Ensure that the cap is completely dry before refitting.
See also:
Fuel-injection control module - removal and refitting
Removal
1 The fuel-injection control module is only
used on KE-Jetronic systems and is located in
the engine compartment behind the heater
plenum chamber and fan motor.
2 Disconnect the battery n ...
Throttle housing - removal and refitting
Note: A new gasket must be used on refitting.
Removal
1 Disconnect the battery negative lead.
2 Depressurise the fuel system as described
in Section 6.
3 Remove the air inlet pipe (see illustrati ...
Crankcase ventilation system check (Every 12 000 miles (20 000 km) or 12
months)
1 Inspect the crankcase ventilation system
for blockage or damage. A blocked hose can
cause a build-up of crankcase pressure,
which in turn can cause oil leaks (see
illustration).
35.1 Loosenin ...