Oil filler cap cleaning - OHVand HCS engines (Every 6000 miles or 6 months)
1 Simply pull the oil filler cap from the rocker cover and, where applicable, disconnect the hose(s) from the cap.
2 Inspect the filler cap, and if necessary clean the cap using clean petrol to remove any deposits.
3 Ensure that the cap is completely dry before refitting.
See also:
Air filter maintenance
Refer to the scheduled maintenance guide for the appropriate intervals
for changing the air filter element.
When changing the air filter element, use only the Motorcraft air filter
element listed ...
Specifications
General
System type:
1.1 litre OHV engines . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . Mechanical contact breaker and coil
1.1 litre CVH engines up to 1986 . . . . . ...
Engine Coolant Temperature (ECT) sensor - removal and refitting
Removal
1 The ECT sensor is screwed into the inlet
manifold.
2 Disconnect the battery negative lead.
3 Partially drain the cooling system as
described in Chapter 1.
4 Disconnect the sensor wirin ...